IN-BUILDING PUBLIC SAFETY RADIO COVERAGE
BDA & ERCES SYSTEMS THAT MEET NEW YORK'S 2025 FIRE CODE — DESIGNED, INSTALLED, AND TESTED IN UPSTATE AND WESTERN NEW YORK
BDA & ERCES SYSTEMS FROM Flower City Communications & Security
NEW YORK NOW REQUIRES A SYSTEM IN ALL NEW CONSTRUCTION OR REMODELED BUILDINGS
Firefighters and police rely on two-way radios to communicate during emergencies, but inside many buildings, those signals can become unreliable. Thick concrete, steel, and coated windows can interfere with public safety radio frequencies, creating dead zones in basements, parking garages, stairways, and elevator areas where emergency responders need dependable communication most.
Since December 31, 2025, the New York State Fire Code has established in-building emergency responder radio coverage requirements for qualifying new construction and building renovations. A Bi-Directional Amplifier (BDA) system, also known as an Emergency Responder Communications Enhancement System (ERCES), captures public safety radio signals outside a building, strengthens and distributes them indoors, and transmits responders’ communications back to the external radio network.
With 55 years of experience in two-way radio communications, Flower City Communications & Security provides comprehensive BDA and ERCES solutions throughout Upstate and Western New York. Our team handles system design, permitting, installation, testing, and certification, along with the annual inspections and testing needed to help building owners maintain compliance and dependable emergency communication.
Not Sure If Your Building Needs an ERCES System?
WHO NEEDS AN ERCES SYSTEM IN NEW YORK
IF YOU'RE CONSTRUCTING A NEW BUILDING, PLAN ON NEEDING ONE
If you’re planning a new building in New York, there’s a good chance you’ll need an ERCES system before you can open your doors. Under the 2025 Fire Code of New York State, the only new buildings exempt from this requirement are single-story buildings of 12,000 square feet or less with no basement. Everything else needs an approved system before opening.
Already have an existing building? You’re not automatically required to install a system, but a major renovation could change that. The requirement can kick in with a Level 3 alteration or relocation, a Level 2 alteration where emergency responders have documented poor radio coverage, or when an existing wired emergency communication system is replaced.
You’ll also need a building permit to install or modify an ERCES system, plus a separate operating permit to keep it running. If you’re building or remodeling in Monroe County or anywhere throughout Upstate or Western New York, Flower City Communications & Security can help you figure out what’s required before construction gets too far along. It’s much easier to address coverage during the design phase than to discover a problem at final inspection.
2025 Fire Code of New York State
§510.1: New Buildings
§1103.2: Existing Buildings
§510.3: Permits
§510.4: Performance
§510.6.1: Annual Testing
Effective December 31, 2025. Requirements and applicability should be confirmed with the local authority having jurisdiction.
Facilities That May Require ERCES Coverage
Supporting public safety communications across a wide range of building types.
Education
Schools, colleges, and campus buildings, above grade and below
Healthcare
Hospitals, clinics, and medical office buildings
Senior Living
Assisted living and skilled nursing, where evacuation is hardest
Warehouse
Distribution centers and high-bay storage with long interior spans
Manufacturing
Plants, mills, and industrial complexes
Parking
Structured and underground parking with poor radio coverage.
Hospitality
Hotels, event space, and conference centers
Multifamily
Apartments, condos, and mixed-use developments
Government
Town, county, and municipal buildings
Data Centers
Hardened shells that block signal by design
Retail
Big-box stores, grocery, and shopping centers
Office
High-rise and multi-tenant office buildings
WHY BUILDINGS NEED IN-BUILDING RADIO COVERAGE
A DEAD RADIO IS A DANGEROUS RADIO
Buildings block radio signals. Thick concrete, steel, and the coating on modern windows all get in the way of the frequencies police and fire departments use. The signal simply can’t get through the walls.
The dead spots are the worst possible places. Basements, parking garages, stairways, and elevator areas are where radios quit — and those are exactly where responders go. The lobby may have five bars; the basement has none.
That radio is how firefighters call for help, order everyone out, and check that their crew made it. If the transmission fails, lives could be at stake.
This one is on the building owner. The fire department isn’t going to fix it — the code says so outright. The system covers the inside of your building, on your dime. And the system has to pass its test, with the results filed with the fire code official, before the building opens. Fail it and you don’t get your certificate of occupancy.
95% OF EVERY FLOOR
99% IN KEY AREAS
CLEAR, USABLE AUDIO
UL 2524 APPROVED GEAR
12 HOURS OF BACKUP POWER
WEATHERPROOF CABINET
BUILT TO NFPA 1225
LICENSED DESIGNER
Want the Full Details?
WHAT IS A BDA / ERCES SYSTEM?
CELL SERVICE FOR THE FIRE DEPARTMENT'S RADIOS, NOT YOUR PHONE
So how do you get a radio signal into a building where it normally can’t reach? That’s exactly what a BDA or ERCES system is designed to do. It takes the public safety radio signal from outside, strengthens it, and carries it into the areas where firefighters and other first responders need it most.
Think of it like cell service inside a building — but for the fire department’s radios, not your phone.
An antenna on the roof grabs the radio signal from outside and points at the dispatch tower. A box called a Bi-Directional Amplifier makes that signal stronger. Small antennas spread it to every floor, every stairway, and the basement, and carry firefighters’ voices back out. The system has its own backup power, so it keeps working if the building loses electricity, and it ties into the fire alarm, so if it ever quits, somebody knows.
It is a life-safety system, not an IT system. It is permitted, inspected, monitored by the fire alarm panel, and tested every year.
1. ANTENNA ON THE ROOF —
Points at the town's radio tower
2. AMPLIFIER + BACKUP POWER —
Boosts the signal, runs 12 hours if power fails
3. ANTENNAS INSIDE —
On every floor, in stairways and basement
4. TIED TO THE FIRE ALARM —
If it breaks, the alarm panel says so
IN-BUILDING COVERAGE SERVICES FROM FLOWER CITY COMMUNICATIONS & SECURITY
FROM BENCHMARK SURVEY THROUGH ANNUAL CERTIFICATION
STEP 01 — WE TEST YOUR BUILDING
STEP 02 — WE GET IT APPROVED
STEP 03 — WE INSTALL IT AND PROVE IT
STEP 04 — WE CHECK IT EVERY YEAR
TESTING, MAINTENANCE, AND CERTIFICATION FOR YOUR BUILDING COVERAGE SYSTEM
AN ERCES SYSTEM IS NOT DONE WHEN THE BUILDING OPENS
Section 510.6.1 of the Fire Code puts yearly testing on the building owner, not the installer and not the fire department. Every year, the system has to be retested for coverage, the amplifier gain has to be verified against its original setting, the backup batteries have to be load-tested for a full hour, and a report has to be filed with the fire code official.
It is the obligation building owners forget, and it is the one that surfaces at the worst possible time — during an inspection, after an incident, or when a tenant’s insurer starts asking questions.
Flower City Communications & Security handles it as a service. We keep your acceptance-test records on file, schedule the annual test, perform it, and file the report. You hear from us before the deadline, not after.
See What a Radio Coverage Test Looks Like
Already have a system someone else installed?
IN-BUILDING CELLULAR COVERAGE SOLUTIONS
NEVER HAVE AN EMPLOYEE OR CUSTOMER MISS A CALL AGAIN
Poor cell signal and dropped calls are among the most common complaints in commercial and industrial buildings, and they cost you productivity and customer satisfaction.
The same Distributed Antenna System infrastructure that carries public safety radio can carry cellular, and planning both together during construction is far less expensive than adding one later. Flower City Communications & Security designs cellular DAS for hospitals, hotels, stadiums, manufacturing plants, and office buildings across Upstate and Western New York.
Important: Cellular coverage and public safety coverage are separate systems with separate rules. A cellular booster will not satisfy the Fire Code, and a non-public-safety amplifier that interferes with the ERCES system has to be corrected or removed.
IN-BUILDING COMMERCIAL RADIO COVERAGE
INCREASE OPERATIONAL EFFICIENCY AND SAFETY WITH IN-BUILDING RADIO COVERAGE
If your own two-way radios drop out in parts of your facility, your staff can’t do the job and safety suffers. We design and implement coverage for multi-floor buildings, underground parking garages, large warehouses, and industrial complexes — from the top floor to the basement.
As a Motorola Solutions partner, we already sell and service the radio systems your teams carry, which means the coverage system and the radios on it come from one vendor who answers for both.
Let's Talk About Your Building
Building new or remodeling in Upstate or Western New York? Call us and we’ll walk you through what the code asks for.